The International System of Units is founded on seven base quantities, each associated with a base unit. These quantities are time, length, mass, electric current, thermodynamic temperature, amount of substance, and luminous intensity. Their respective units are the second (s), metre (m), kilogram (kg), ampere (A), kelvin (K), mole (mol), and candela (cd). The modern SI is defined by fixing exact numerical values for seven defining constants: the caesium-133 hyperfine transition frequency, the speed of light in vacuum, the Planck constant, the elementary charge, the Boltzmann constant, the Avogadro constant, and the luminous efficacy of a specified monochromatic radiation. The base units are therefore defined through physical constants rather than depending on physical artefacts. Unit symbols are internationally standardized and remain unchanged between languages. They are generally lowercase unless the unit is named after a person, in which case the symbol begins with an uppercase letter. For example, the unit newton has symbol N, while metre has symbol m. The unit name is written in lowercase even when derived from a person's name. Unit symbols do not take plural forms and are not followed by periods unless the period is required by sentence punctuation. A space separates a numerical value from its unit symbol, except for certain conventional angle symbols such as °, ′, and ″. The kelvin is written K, not °K. Temperature differences may be expressed in kelvins or degrees Celsius, with an interval of 1 K equal in magnitude to an interval of 1 °C. The mole represents an amount of substance containing exactly 6.02214076 × 10²³ specified elementary entities. The entity must be identified when necessary, such as atoms, molecules, ions, or electrons.
SI Base Units, Unit Symbols and Writing Conventions
Explains the seven International System of Units (SI) base quantities and their corresponding base units, symbols, definitions, and writing conventions. It establishes the foundation for expressing all SI measurements consistently and for constructing derived units.
Q = {Q}[Q]; T(K) = t(°C) + 273.15
Explanation
Variables
| Symbol | Meaning | Unit |
|---|---|---|
s | SI base unit of time | second |
m | SI base unit of length | metre |
kg | SI base unit of mass | kilogram |
A | SI base unit of electric current | ampere |
K | SI base unit of thermodynamic temperature | kelvin |
mol | SI base unit of amount of substance | mole |
cd | SI base unit of luminous intensity | candela |
Example or application
A worked example has not yet been added.
Definition
An SI base unit is one of the seven fundamental units defined by the International System of Units and used as the foundation for expressing all SI physical quantities.
Purpose
Provides the internationally agreed foundation for scientific measurements, enabling different countries, disciplines, laboratories, and engineering systems to communicate quantities using a common set of units.
Importance
The SI base units ensure consistency, traceability, and comparability in measurement. Their definitions based on fundamental constants support high-precision metrology, technological development, scientific research, and international trade.
Seven Base Quantities
| Quantity | Quantity Symbol | Unit Name | Unit Symbol | Dimension Symbol | Definition Basis |
|---|---|---|---|---|---|
Time | t | second | s | T | Defined by fixing the caesium-133 hyperfine transition frequency ΔνCs at exactly 9,192,631,770 Hz. |
Length | l | metre | m | L | Defined by fixing the speed of light in vacuum c at exactly 299,792,458 m/s. |
Mass | m | kilogram | kg | M | Defined by fixing the Planck constant h at exactly 6.62607015 × 10⁻³⁴ J·s. |
Electric current | I | ampere | A | I | Defined by fixing the elementary charge e at exactly 1.602176634 × 10⁻¹⁹ C. |
Thermodynamic temperature | T | kelvin | K | Θ | Defined by fixing the Boltzmann constant kB at exactly 1.380649 × 10⁻²³ J/K. |
Amount of substance | n | mole | mol | N | Defined by fixing the Avogadro constant NA at exactly 6.02214076 × 10²³ mol⁻¹. |
Luminous intensity | Iv | candela | cd | J | Defined by fixing the luminous efficacy Kcd at exactly 683 lm/W for monochromatic radiation of frequency 540 × 10¹² Hz. |
Unit Writing Conventions
Leave a space between the numerical value and the unit symbol: 15 m, 20 kg, and 300 K.
Do not pluralize unit symbols: write 5 kg, not 5 kgs.
Do not add a period after a unit symbol unless it ends a sentence.
Use uppercase symbols for units named after people, such as N, J, Pa, and W.
Use lowercase symbols for units not named after people, such as m, s, mol, and cd.
Unit names are written in lowercase in running text, including names derived from people.
Do not combine multiple prefixes on a single unit.
Use a space or a centred dot between unit factors where necessary to avoid ambiguity.
Use parentheses or negative exponents to make complex denominators clear.
Write the kelvin as K without a degree sign.
Temperature Conventions
Kelvin
T = 273.15 K
Celsius
t = 0 °C
Conversion
T(K) = t(°C) + 273.15
Temperature Difference
A temperature difference of 1 K is equal to a temperature difference of 1 °C.
Warning
Absolute thermodynamic temperature is expressed in kelvins, whereas Celsius temperature is expressed in degrees Celsius.
Case Sensitive Examples
| Symbol | Meaning |
|---|---|
m | metre |
M | Not an SI base-unit symbol; may represent molar concentration in certain conventions. |
K | kelvin |
k | SI prefix symbol for kilo, meaning 10³. |
A | ampere |
a | SI prefix symbol for atto, meaning 10⁻¹⁸. |
Worked Examples
| Problem | Solution |
|---|---|
Convert 25 °C into kelvins. | T = 25 + 273.15 = 298.15 K. |
Express 0.005 kilogram using grams. | 0.005 kg × 1000 g/kg = 5 g. |
Identify the SI base unit of electric current. | The ampere, symbol A. |
Common Errors
Writing °K instead of K.
Using Kg instead of kg.
Writing unit symbols in plural form.
Confusing the unit name with its symbol.
Omitting the space between a numerical value and a unit symbol.
Using the Celsius scale as though its zero point were absolute zero.
Applications
International scientific measurement and metrology.
Laboratory calibration and instrument standards.
Engineering design and manufacturing specifications.
Physical constant definitions and scientific data reporting.
Temperature, electrical, mass, and length measurement.
Reference
BIPM, The International System of Units (SI Brochure), 9th edition.
NIST Special Publication 330, The International System of Units (SI).
NIST Special Publication 811, Guide for the Use of the International System of Units (SI).
IUPAC, Quantities, Units and Symbols in Physical Chemistry (Green Book).
Related Topic
SCI-REF-006-101
SCI-REF-006-103
SCI-REF-006-104
SCI-REF-006-105
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.
Suggest a correction or source · More in Scientific Symbols & Notation