Definition
SI derived units are units obtained by combining SI base units according to the mathematical definitions of physical quantities. Some derived units have special names and symbols.
Formation Principle
Derived units are constructed by multiplying or dividing base units and raising them to appropriate powers according to the defining physical equation.
Major Derived Units
| Quantity | Unit Name | Symbol | Base Unit Expression | Defining Relationship |
|---|---|---|---|---|
Area | square metre | m² | m² | Area = length × width |
Volume | cubic metre | m³ | m³ | Volume = length × width × height |
Frequency | hertz | Hz | s⁻¹ | Frequency = 1 ÷ time period |
Force | newton | N | kg·m·s⁻² | Force = mass × acceleration |
Pressure | pascal | Pa | kg·m⁻¹·s⁻² | Pressure = force ÷ area |
Energy and work | joule | J | kg·m²·s⁻² | Work = force × displacement |
Power | watt | W | kg·m²·s⁻³ | Power = energy ÷ time |
Electric charge | coulomb | C | A·s | Charge = electric current × time |
Electric potential difference | volt | V | kg·m²·s⁻³·A⁻¹ | Voltage = energy ÷ electric charge |
Electrical resistance | ohm | Ω | kg·m²·s⁻³·A⁻² | Resistance = voltage ÷ current |
Capacitance | farad | F | kg⁻¹·m⁻²·s⁴·A² | Capacitance = electric charge ÷ voltage |
Magnetic flux | weber | Wb | kg·m²·s⁻²·A⁻¹ | Magnetic flux = magnetic field × area for a perpendicular uniform field |
Magnetic flux density | tesla | T | kg·s⁻²·A⁻¹ | Magnetic flux density = magnetic flux ÷ area |
Inductance | henry | H | kg·m²·s⁻²·A⁻² | Inductance = magnetic flux linkage ÷ current |
Luminous flux | lumen | lm | cd·sr | Luminous flux is the luminous intensity integrated over a solid angle. |
Illuminance | lux | lx | lm/m² | Illuminance = luminous flux ÷ illuminated area |
Radioactive activity | becquerel | Bq | s⁻¹ | Activity = number of nuclear decays per unit time |
Absorbed dose | gray | Gy | m²·s⁻² | Absorbed dose = energy imparted ÷ mass |
Equivalent dose | sievert | Sv | m²·s⁻² | Equivalent dose is calculated from absorbed dose and radiation weighting factors. |
Catalytic activity | katal | kat | mol·s⁻¹ | Catalytic activity = amount of substance transformed ÷ time |
Unit Relationships
1 N = 1 kg·m/s²
1 Pa = 1 N/m²
1 J = 1 N·m
1 W = 1 J/s
1 C = 1 A·s
1 V = 1 J/C
1 Ω = 1 V/A
1 F = 1 C/V
1 Wb = 1 V·s
1 T = 1 Wb/m²
1 H = 1 Wb/A
1 lm = 1 cd·sr
1 lx = 1 lm/m²
1 Bq = 1 s⁻¹
1 Gy = 1 J/kg
1 Sv = 1 J/kg
1 kat = 1 mol/s
Special Note
The steradian (sr) is a dimensionless derived SI unit used for solid angle. The gray and sievert share the same SI dimensional expression, but they represent different radiation quantities and are not interchangeable.
Worked Examples
| Problem | Calculation | Answer |
|---|---|---|
Express 5 newtons in SI base units. | 5 N = 5 kg·m/s² | 5 kg·m·s⁻² |
Express 60 watts in joules per second. | 60 W × 1 J/(1 W·s) = 60 J/s | 60 J/s |
Express 4 kilopascals in pascals. | 4 kPa × 1,000 Pa/kPa = 4,000 Pa | 4,000 Pa |
Conversion Method
Identify the derived physical quantity.
Write its defining mathematical relationship.
Express the unit using SI base units.
Identify the conversion factor for each unit component.
Apply the factors with the correct powers.
Check that the resulting dimensions remain consistent.
Common Mistakes
Confusing units that share the same dimensions but represent different physical quantities.
Ignoring exponents when converting squared or cubed units.
Assuming all derived units have special names.
Confusing luminous flux with illuminance.
Treating gray and sievert as interchangeable simply because their dimensions match.
Applications
Converting mechanical and electrical measurements.
Deriving scientific equations.
Checking the dimensional consistency of formulas.
Interpreting engineering specifications.
Converting measurements used in physics, chemistry and radiation science.
Knowledge Check
| Question | Answer |
|---|---|
What is the SI base-unit expression for one joule? | 1 J = 1 kg·m²/s². |
What is the SI derived unit of pressure? | Pascal (Pa), equivalent to N/m². |
Are gray and sievert interchangeable? | No. They represent different radiation quantities despite sharing the same dimensional expression. |