Definition

The International System of Units (SI) is the internationally accepted system of measurement used to define and communicate physical quantities consistently across science, technology, industry and everyday applications.

System Structure

Base Units

Seven base units representing seven independent base quantities.

Derived Units

Units formed from combinations of base units.

Prefixes

Standard prefixes used to express decimal multiples and submultiples of units.

Unit Symbols

Internationally standardized symbols used to represent units.

Defining Constants

Seven defining constants establish the definitions of the SI base units.

Seven Base Units

  • metre (m) for length

  • kilogram (kg) for mass

  • second (s) for time

  • ampere (A) for electric current

  • kelvin (K) for thermodynamic temperature

  • mole (mol) for amount of substance

  • candela (cd) for luminous intensity

Important SIConventions

RuleExplanationCorrectIncorrect

Unit symbols are not abbreviations.

They do not normally take plural forms or full stops.

5 kg

5 kgs or 5 kg.

A space separates the numerical value from the unit symbol.

The numerical value and unit symbol are written as separate elements.

25 m

25m

Unit symbols are case-sensitive.

Uppercase and lowercase letters can represent different units.

MW for megawatt; mW for milliwatt

Treating MW and mW as equivalent.

Symbols named after people use uppercase letters.

The symbol is capitalized, while the written unit name normally begins with a lowercase letter.

newton (N), joule (J), pascal (Pa)

Writing the unit name as Newton in ordinary scientific text.

Unit symbols do not change in the plural.

The same symbol is used for singular and plural quantities.

1 s and 10 s

10 ss

Compound units must be written unambiguously.

Multiplication and division should be represented using accepted notation.

N·m or N m

Using unclear combinations of symbols.

Prefixes attach directly to unit symbols.

No space is placed between a prefix symbol and the unit symbol.

km, mg, μs

k m or m g

The kilogram is the SI base unit of mass.

Mass prefixes are commonly attached to gram rather than adding another prefix to kilogram.

mg, g, kg, Mg

Treating kg as a prefix-free gram unit.

Unit Writing Examples

QuantityCorrect Notation

Length

12.5 m

Mass

250 g

Time

60 s

Temperature

300 K

Force

20 N

Pressure

101.325 kPa

Derived Unit Notation

FormMeaning

m/s

Metres per second

m·s⁻¹

Metres multiplied by the reciprocal of seconds

kg/m³

Kilograms per cubic metre

J/(mol·K)

Joules per mole-kelvin

Prefix Rules

  • A prefix represents a specified power of ten.

  • The prefix symbol is attached directly to the unit symbol.

  • Only one prefix is normally used with a unit.

  • Prefixes are case-sensitive.

  • Prefix powers must also be applied to squared and cubed units.

Conversion Example

Problem

Convert 2.5 kilometres into metres using SI conventions.

Relationship

1 km = 10³ m

Calculation

2.5 × 10³ m

Answer

2,500 m

Why Standardization Matters

  • It makes scientific measurements internationally understandable.

  • It reduces ambiguity in technical communication.

  • It supports consistent instrument calibration.

  • It makes scientific data easier to compare.

  • It improves reliability in engineering and industrial calculations.

Common Mistakes

  • Using incorrect capitalization in unit symbols.

  • Omitting the space between a number and its unit.

  • Adding plural letters to unit symbols.

  • Using multiple prefixes on a single unit.

  • Confusing the written unit name with its symbol.

  • Writing compound units in an ambiguous form.

Applications

  • Scientific publications and research reports.

  • Engineering drawings and technical specifications.

  • Laboratory measurement records.

  • International trade and manufacturing.

  • Education and scientific data communication.

Knowledge Check

QuestionAnswer

What does SI stand for?

International System of Units.

Should a space be written between 25 and m?

Yes. The correct notation is 25 m.

Are MW and mW equivalent?

No. MW means megawatt, while mW means milliwatt.

Example or application

A worked example has not yet been added.

Importance

Correct use of SI conventions ensures that scientific measurements are clearly written, consistently interpreted and suitable for international communication.

Sources and verification

Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.

  • Source verification pending; check an authoritative textbook, university, standards body, or peer-reviewed source.