A stock solution is a prepared solution with a known concentration that is used to make one or more working solutions. A diluted solution is produced by transferring a measured quantity of stock solution and adding solvent until the required final volume is reached. The dilution equation C₁V₁ = C₂V₂ determines the stock volume needed. If multiple dilutions are performed sequentially, each step must use the concentration and volume appropriate to that stage. Accurate preparation also requires suitable volumetric equipment and attention to solution compatibility.
Stock Solution and Diluted Solution Calculations
Applies concentration and dilution relationships to prepare working solutions from concentrated stock solutions.
C₁V₁ = C₂V₂
Dilution factor = C₁/C₂ = V₂/V₁
For serial dilutions: Cfinal = Cinitial × (V₁/V₂)₁ × (V₁/V₂)₂ × ...
Explanation
Variables
C₁
Stock-solution concentration.
V₁
Volume of stock solution transferred.
C₂
Target concentration.
V₂
Final working-solution volume.
Example or application
Prepare 250 mL of 0.20 M solution from a 2.0 M stock: V₁ = (0.20 × 250)/2.0 = 25 mL. Transfer 25 mL of stock and add solvent until the final volume is 250 mL.
Definition
Stock-solution preparation is the process of using a known concentrated solution to produce a solution of lower specified concentration.
Purpose
Provides a practical method for preparing lower-concentration solutions from concentrated reagents.
Importance
Stock solutions reduce repeated weighing, improve preparation consistency, and support efficient laboratory workflows.
Preparation Procedure
Confirm the stock concentration and target concentration.
Choose the required final volume.
Calculate the stock volume using C₁V₁ = C₂V₂.
Measure the calculated stock volume accurately.
Transfer it to a suitable volumetric container.
Add solvent until the final volume reaches the calibration mark.
Mix thoroughly and label the solution with its identity, concentration, and preparation details.
Serial Dilution Example
A 1:10 dilution followed by another 1:10 dilution gives an overall dilution factor of 100. A starting concentration of 1.0 M becomes 0.010 M.
Common Mistakes
Adding the calculated stock volume to the full target volume of solvent.
Using the wrong stock concentration.
Failing to mix the diluted solution uniformly.
Forgetting that each serial dilution changes the concentration for the next step.
Sources and verification
Sources are shown as provided in the project data. Not every source has yet been independently verified. Please report errors or missing citations.
- Standard Analytical Chemistry Textbooks
- NIST Laboratory Measurement Guidance
Suggest a correction or source · More in Conversions & Equivalences