Learning Objective
Calculate uncertainty in converted quantities when measurements are multiplied, divided, raised to powers or combined.
Core Concept
Uncertainty propagation describes how uncertainties in input measurements contribute to the uncertainty of a calculated output.
Scientific Background
A scientific result may depend on several measured quantities. Even when every input is converted correctly, the final result carries uncertainty from the measurements and any uncertain constants or factors used in the calculation.
Conversion Principle
For independent input quantities, standard uncertainties can be propagated using mathematical sensitivity coefficients. Simplified relative-uncertainty rules apply to common products and powers.
Important Formulas
| Operation | Formula | Description |
|---|---|---|
Exact linear conversion | y = kx; u(y) = |k|u(x) | An exact multiplicative conversion scales the absolute uncertainty by the magnitude of the conversion factor. |
Addition or subtraction | u(y) = √(u₁² + u₂²) | For independent measurements, standard absolute uncertainties combine by root-sum-of-squares. |
Multiplication or division | uᵣ(y) = √(uᵣ(x₁)² + uᵣ(x₂)²) | For independent inputs, relative standard uncertainties combine by root-sum-of-squares. |
Power relationship | y = xⁿ; approximately uᵣ(y) = |n|uᵣ(x) | For small uncertainty and a nonzero input, the relative uncertainty is multiplied by the absolute value of the exponent. |
General Propagation Formula
u_c²(y) = Σ[(∂f/∂xᵢ)²u²(xᵢ)] for independent input quantities
Variables
U c(y)
Combined standard uncertainty of the output.
F
The mathematical function relating input quantities to the output.
Xᵢ
An input measurement.
∂f/∂xᵢ
Sensitivity coefficient for the corresponding input.
U(xᵢ)
Standard uncertainty of that input.
Worked Examples
| Problem | Calculation | Answer | Explanation |
|---|---|---|---|
A length is 2.00 ± 0.02 m. Convert it into centimetres. | y = 100 × 2.00 = 200 cm; u(y) = 100 × 0.02 = 2 cm | 200 ± 2 cm | An exact conversion factor scales the absolute uncertainty by the same amount. |
Two independent lengths are 5.0 ± 0.1 m and 3.0 ± 0.2 m. Find the uncertainty in their sum. | u = √(0.1² + 0.2²) = √0.05 ≈ 0.224 m | 8.0 ± 0.22 m, approximately | The central values are added, while independent standard uncertainties combine by root-sum-of-squares. |
Important Conditions
The simple formulas assume independent input uncertainties unless stated otherwise.
Correlated measurements require covariance terms.
The formulas are generally first-order approximations.
Large or nonlinear uncertainties may require more advanced propagation methods.
The uncertainty type and confidence interpretation should be stated.
Common Mistakes
Adding independent standard uncertainties directly in every calculation.
Using absolute uncertainty rules for multiplication without considering relative uncertainty.
Ignoring correlations between measurements.
Assuming an exact conversion factor introduces measurement uncertainty.
Rounding intermediate uncertainty calculations too early.
Practical Applications
Experimental physics.
Chemical analysis.
Engineering measurements.
Calibration procedures.
Scientific research data processing.
Knowledge Check
| Question | Answer | Explanation |
|---|---|---|
What happens to the absolute uncertainty when a measurement is multiplied by an exact factor of 10? | The absolute uncertainty is also multiplied by 10. | The conversion scales both the central value and its absolute uncertainty. |
Source
JCGM 100 - Guide to the Expression of Uncertainty in Measurement
NIST Technical Note 1297
BIPM - International Vocabulary of Metrology