Learning Objective
Understand resonance in air columns, node and antinode formation, end correction and the use of resonance measurements to determine sound speed.
Definition
A resonance tube is a tube containing an air column whose effective length can be varied to produce resonance with a sound source.
Scientific Background
Sound waves reflected at the end of a tube interfere with incoming waves. At particular air-column lengths, standing-wave resonance occurs. A tube closed at one end supports a displacement node near the closed end and an antinode near the open end.
Components
| Name | Function |
|---|---|
Resonance Tube | Contains the air column in which standing waves form. |
Adjustable Water Reservoir or Piston | Changes the effective air-column length. |
Sound Source | Provides a sound signal of known or controlled frequency. |
Length Scale | Measures the air-column length. |
Temperature Sensor | Records air temperature when sound speed is being determined. |
Working Principle
Principle
Standing-Wave Resonance
Explanation
At resonance, reflected and incident waves combine to form a standing-wave pattern. For a tube closed at one end, successive ideal resonance lengths are separated by approximately half a wavelength.
First Resonance
L + e ≈ λ/4
Successive Resonances
L2 - L1 ≈ λ/2
Wave Equation
v = fλ
Variables
| Symbol | Meaning |
|---|---|
L | Measured air-column length |
e | End correction |
λ | Wavelength |
v | Sound speed |
f | Frequency |
Measurement Procedure
Set up the resonance tube securely.
Select a sound source with a known frequency.
Adjust the air-column length gradually.
Identify a clear resonance condition.
Record the corresponding air-column length.
Find a second resonance length where possible.
Calculate wavelength from the separation of successive resonances.
Determine sound speed using v = fλ.
Record temperature and consider end correction.
Worked Examples
| Problem | Calculation | Answer | Explanation |
|---|---|---|---|
Two successive resonance lengths in a closed tube differ by 0.34 m. Calculate the wavelength. |
| 0.68 m | The difference between successive resonances is approximately half a wavelength. |
Accuracy And Limitations
Limitations
End correction affects the effective air-column length.
Resonance may be broad rather than sharply defined.
Background noise can make resonance identification difficult.
The sound speed changes with air temperature.
The source frequency must be known accurately.
Practical Applications
Determining the speed of sound.
Measuring acoustic wavelength.
Studying standing waves.
Investigating resonance in air columns.
Teaching wave interference and boundary conditions.
Common Errors
Ignoring end correction.
Reading the air-column length incorrectly.
Changing the sound-source frequency during measurement.
Confusing successive resonances with adjacent wave nodes.
Failing to account for temperature.
Maintenance And Safety
Keep the tube clean and free from obstructions.
Handle glass tubes carefully.
Secure water reservoirs and movable components.
Avoid excessive sound levels.
Keep electrical sound sources away from spilled water.
Knowledge Check
| Question | Answer | Explanation |
|---|---|---|
What is the separation between successive resonance lengths in a closed tube? | Approximately half a wavelength. | Successive resonance conditions differ by λ/2. |
Why is end correction considered? | Because the displacement antinode is formed slightly outside the physical open end. | The effective air-column length is therefore slightly greater than the measured tube length. |