Definition
A NOₓ analyzer is an instrument used to measure nitric oxide (NO), nitrogen dioxide (NO₂), or their combined concentration, depending on the analyzer design.
Scientific Background
Nitrogen oxides are produced by combustion and other high-temperature processes. They participate in atmospheric reactions that contribute to ozone formation, nitrate aerosol formation, and other air-quality effects.
Instrument Types
| Name | Principle |
|---|---|
Chemiluminescence analyzer | Measures light emitted during the reaction of nitric oxide with ozone. |
Differential optical absorption spectroscopy | Uses wavelength-dependent absorption features to estimate atmospheric gas concentrations. |
Electrochemical sensor | Uses an electrochemical response to estimate selected nitrogen oxide concentrations. |
Components
Sample inlet
Sample conditioning system
Reaction or optical measurement chamber
Detector
Signal processor
Calibration interface
Working Principle
In chemiluminescence systems, nitric oxide reacts with ozone and produces electronically excited nitrogen dioxide. The emitted light is measured. A converter may be used to transform nitrogen dioxide into nitric oxide for total NOₓ measurement.
Important Measurements
| Name | Description |
|---|---|
NO | Nitric oxide concentration. |
NO₂ | Nitrogen dioxide concentration. |
NOₓ | A reported combined nitrogen oxides quantity, commonly NO plus NO₂. |
Measurement Units
ppb
ppm
µg/m³
Accuracy And Limitations
Converter efficiency can affect NO₂ and NOₓ results.
Other nitrogen-containing compounds may interfere with some conversion methods.
Sample-line reactions can alter measured concentrations.
Humidity and temperature can affect some sensor technologies.
Calibration
Use suitable NO calibration standards.
Verify zero response.
Check converter performance where applicable.
Follow approved reference measurement procedures.
Practical Applications
Urban air monitoring
Road traffic pollution studies
Industrial emission measurement
Atmospheric chemistry research
Environmental compliance assessment
Maintenance And Safety
Inspect sample lines and filters.
Maintain reaction chamber and converter performance according to manufacturer guidance.
Use certified calibration gases.
Follow safe handling procedures for calibration gas systems.
Knowledge Check
| Question | Answer |
|---|---|
Which two gases are commonly included in reported NOₓ measurements? | Nitric oxide (NO) and nitrogen dioxide (NO₂). |
Which optical phenomenon is used in a conventional chemiluminescence NO analyzer? | Light emitted by an excited reaction product. |