Definition
A hygrometer is an instrument used to measure atmospheric moisture content.
Scientific Background
Water vapor is an important atmospheric component that influences cloud formation, precipitation, evaporation, heat exchange, and human comfort. Relative humidity compares actual water vapor pressure with saturation vapor pressure at the same temperature.
Instrument Types
| Name | Principle |
|---|---|
Capacitive hygrometer | Measures changes in capacitance caused by moisture absorption in a sensing material. |
Resistive hygrometer | Measures changes in electrical resistance associated with moisture. |
Psychrometer | Uses temperature differences between dry-bulb and wet-bulb thermometers to estimate humidity. |
Chilled-mirror hygrometer | Determines dew point from the temperature at which condensation forms on a cooled surface. |
Components
Humidity-sensitive element
Temperature sensor
Signal processing unit
Display or data logger
Protective housing
Working Principle
Different hygrometers use changes in electrical properties, evaporation-related cooling, or condensation temperature to estimate atmospheric moisture.
Formulas
| Name | Expression | Variables |
|---|---|---|
Relative humidity | RH = (e / es) × 100% | RH Relative humidity. E Actual water vapor pressure. Es Saturation vapor pressure at the same temperature. |
Dew point relationship | Dew point is the temperature at which air becomes saturated when cooled at approximately constant pressure and water vapor content. |
Worked Examples
| Problem | Solution |
|---|---|
The actual water vapor pressure is 1.5 kPa and saturation vapor pressure is 2.0 kPa. Calculate relative humidity. | RH = (1.5 / 2.0) × 100 = 75%. |
Measurement Units
Relative humidity: %
Temperature: °C
Vapor pressure: Pa or kPa
Dew point: °C
Accuracy And Limitations
Temperature changes can influence sensor response.
Condensation and contamination can affect measurements.
Some sensors show drift during prolonged exposure to extreme humidity.
Poor ventilation around the sensor can produce unrepresentative readings.
Calibration
Use suitable humidity reference standards.
Compare readings with a calibrated reference hygrometer.
Follow the manufacturer's sensor-conditioning instructions.
Practical Applications
Weather monitoring
Climate research
Agricultural storage
Indoor environmental assessment
Industrial environmental control
Hydrological studies
Maintenance And Safety
Protect the sensor from dust and chemical contamination.
Avoid direct contact with the sensing element.
Allow the instrument to equilibrate with the measurement environment.
Maintain temperature and humidity calibration records.
Knowledge Check
| Question | Answer |
|---|---|
What does 75% relative humidity mean? | Actual water vapor pressure is 75% of saturation vapor pressure at the same temperature. |
Which hygrometer uses wet-bulb and dry-bulb temperatures? | A psychrometer. |